HGT — the height invariant

There are two HGT codes. Both say that written values contradict each other.

CodeSeverityWhat it says
HGT01errorCeiling height plus the slab above exceeds the storey height — it eats into the floor above
HGT02errorA ceiling height that pierces a storey is declared under a partial void

This is the sectional counterpart of overlapping in plan. check calls two regions overlapping on one level a contradiction (GEO02); on exactly the same footing it calls a lower ceiling punching through the floor above a contradiction. Both are about written data failing to hold together, not about whether the building is any good. That is why HGT stays on the check side.

The invariant

For every space:

effective ceiling height + the slab of the level above ≤ storey height
  • The effective ceiling height is the space's own h: if it has one, otherwise the h: of the level it sits on. A space's h beats its level's.
  • The slab above is the next level's slab: (floor-construction thickness — structural slab, plenum and finish).
  • The storey height is the difference between the next level's z and this level's z. Storey height is never written; it is derived from the levels' z.
  • The tolerance is 0.5mm, so rounding never trips this.

koyu levels shows the stack-up as a section in text.

koyu levels examples/house/main.muro
R	z:5800	slab:500
L2	z:2900	h:2400	slab:500
  ↑ storey height 2900 = ceiling 2400 + slab 500
L1	z:0	h:2400	slab:400
  ↑ storey height 2900 = ceiling 2400 + slab 500

Who gets checked

The invariant is asked only of spaces that satisfy all of the following.

  • There is a level above. The top storey has no floor above it to collide with.
  • Something above overlaps it. A space with storeys above it but nothing directly over its own footprint is not asked. A level above that carries no spaces at all counts as covering everything.
  • It is not semi-outdoor. A space meeting the exterior across type:open or air:1 — a balcony, a terrace, an external stair — has no ceiling.
  • It carries no vertical circulation declaration. The ceiling over a space with stair:, ramp:, escalator: or lift: follows the flight above it and cannot be stated as one number. This is a declarative exemption.
  • Both the slab above and the effective ceiling height are determined. Without either, the inequality cannot be formed. That state is missing information, not a broken invariant, so SUF01 and SUF03 say it instead and HGT stays quiet.

That last point bites. Forget slab: on the level above and the storey below goes unchecked and stays green. Run --strict so SUF03 is caught.

HGT01 — it collides with the storey above

error

grid X 0 3600
grid Y 0 4000
level L1 0 h:2800 slab:400
level L2 3000 h:2400 slab:400
space /L1/a room X1..X2 Y1..Y2
space /L2/a room X1..X2 Y1..Y2
/L1/a collides into the floor above: ceiling height 2800 + L2's slab 400 = 3200 > storey height 3000

Cause — a ceiling height of 2800 plus a floor construction of 400 exceeds the storey height of 3000. The message prints all three numbers, so which one to move is settled on the spot.

Fix — move one of the three.

  • Lower the ceiling height — level L1 0 h:2400 slab:400
  • Thin the floor construction — level L2 3000 h:2400 slab:200
  • Raise the storey — level L2 3400 h:2400 slab:400

To lower the ceiling of one room only, write it on the space rather than on the level.

grid X 0 3600
grid Y 0 4000
level L1 0 h:2800 slab:400
level L2 3000 h:2400 slab:400
space /L1/a room X1..X2 Y1..Y2 h:2400
space /L2/a room X1..X2 Y1..Y2

If you meant to pierce the storey, that is a void — see HGT02 below.

HGT02 — insufficient coverage under a partial void

error

grid X 0 3600 7200
grid Y 0 4000
level L1 0 h:5400 slab:400
level L2 3000 h:2400 slab:400
space /L1/a room X1..X3 Y1..Y2
space /L2/v void X1..X2 Y1..Y2
space /L2/b room X2..X3 Y1..Y2
boundary /L1/a /L2/v type:void
/L1/a collides into the floor above: ceiling height 5400 + L2's slab 400 = 5800 > storey height 3000. The void covers only 50.0% — under a partial void keep the ceiling height within the storey height (the height of the void part is derived)

Cause — a type:void boundary is a declarative exemption from the height invariant, but the exemption reaches only as far as the void covers the lower storey's plan. The example voids half the lower storey yet declares a ceiling height of 5400, piercing the storey. Over the other half there is a floor, and that part cannot be 5400.

The exemption is total only at a coverage ratio of 99% or more. The message prints the coverage to one decimal — a grain that cannot collide with the threshold.

Fix — bring the lower storey's ceiling height inside the storey.

grid X 0 3600 7200
grid Y 0 4000
level L1 0 h:2400 slab:400
level L2 3000 h:2400 slab:400
space /L1/a room X1..X3 Y1..Y2
space /L2/v void X1..X2 Y1..Y2
space /L2/b room X2..X3 Y1..Y2
boundary /L1/a /L2/v type:void

The height of the void part is never declared. It is derived from the void relation. The lower storey's ceiling height is the ceiling height where there is a floor above, not the height of the void.

To make the whole thing a void, give the void space the same region as the storey below. Coverage is then 100% and the storey-piercing ceiling height passes.

grid X 0 3600
grid Y 0 4000
level L1 0 h:5400 slab:400
level L2 3000 h:2400 slab:400
space /L1/a room X1..X2 Y1..Y2
space /L2/v void X1..X2 Y1..Y2
boundary /L1/a /L2/v type:void

What HGT does not say

There is not one architectural judgement about height anywhere in koyu. Eaves height, maximum height, road setback lines, north-side setback, shadow studies, minimum ceiling heights — none of these exist in check or in koyu validate. About height, koyu says only whether the written numbers add up.

The two height-adjacent judgements koyu validate does carry are the proportion of a derived stair's tread and riser (stair.proportion) and a derived ramp's slope (run.slope). Both are cautions about a derived shape, not statutory height limits.