koyu light

For spaces declared with daylight:1, lists whether the effective window area reaches one seventh of the floor area.

Arguments

koyu light <entry.muro>

Takes one entry path.

Flags

None.

Output

One line per room in scope, then a summary.

npx tsx src/cli.ts light examples/house/main.muro
✔ /home/ldk	LDK	window 7.54 m2 / floor 39.75 m2 = 1/5.3 (needs 1/7 ≈ 5.68 m2)
✔ /home/bed1	主寝室	window 5.72 m2 / floor 26.50 m2 = 1/4.6 (needs 1/7 ≈ 3.79 m2)
✔ Every room meets 1/7 — 2 rooms in scope (a rough judgement with no correction factor — this is validation, not what check guarantees)

The columns are tab-separated: mark / path / name / the numbers. 1/5.3 is floor over window; a denominator larger than 7 means it falls short.

When a room falls short it gets , and the summary gives the count.

npx tsx src/cli.ts light dark.muro
✖ /L1/a	居室A	window 0.36 m2 / floor 16.20 m2 = 1/45.0 (needs 1/7 ≈ 2.31 m2)
✖ /L1/b	居室B	window 0.00 m2 / floor 16.20 m2 = no window (needs 1/7 ≈ 2.31 m2) ⚠ windows without h: are not counted
✖ Short of 1/7: 2 of 2 rooms (this is a validation judgement)

A room where no window could be counted reads no window.

Windows without h

A window with no h cannot have its area counted. That room's line gains ⚠ windows without h: are not counted at the end. The /L1/b above is written window w:2600 edge:E and still comes out as 0.00 m2 — it has a width but no height.

The numbers on a line carrying that warning are a lower bound, not the actual window area.

Scope is never inferred from the type

Only spaces that write daylight:1 are judged. The type is not consulted. Which rooms the one-seventh rule applies to is a legal judgement and cannot be derived from a type: habitable rooms in an apartment building are in scope, guest rooms in a hotel are not, and the single word room cannot express the difference.

With nothing in scope, no judgement runs at all.

npx tsx src/cli.ts light examples/office.muro
Nothing is in daylight scope (write daylight:1 on the rooms to be judged)

Do not read this as a pass. Forgetting to write daylight:1 produces exactly the same output.

It is a rough judgement

No correction factor is applied. It does not look at where in the wall the opening sits, at the distance to the neighbouring boundary, or at an overhang. It is an early warning pitched at the resolution of schematic design, not a daylight calculation for a building permit.

And this is a judgement, not what check guarantees. A green light with a red check means the composition is broken; a green check with a red light means there are not enough windows. The two look at different things.

Exit codes

Exit codeMeaning
0Every room in scope meets 1/7, or nothing is in scope
1Some room falls short, or the input could not be read
2No file path was given (usage is printed)

Nothing in scope exits 0. Put light in CI for a model that writes no daylight:1 anywhere, and green comes back having looked at nothing.

Its relation to validate